Two phase connection
1.
Remove the cable end sleeve from
black and brown wires.
2.
Remove insulation of the brown and
black cable ends.
3.
Apply a new wire end sleeve of 1.5
mm² on each cable end. (Special tool
required)
WARNING!
All electrical connections must be
made by a qualified electrician.
CAUTION!
Do not drill or solder the wire
ends. This is strictly forbidden!
WARNING!
Do not connect the cable without
cable end sleeve.
N
L1
N
L
230V~ 400V 2~N
L2
One phase connection — 230 V~
Two phase connection — 400 V 2 ~
N
Green — yellow Green — yellow
N Blue and gray Blue and gray N
L Black and brown Black L1
Brown L2
8.3 Assembly
min.
50mm
min.
500mm
min.
2mm
16